Research Article

Mechanical Analysis of the Failure Characteristics of Stope Floor Induced by Mining and Confined Aquifer

Table 1

Analysis of measured values and theoretical values of floor failure depth in five coal mines.

Coal minesH (m)M (m)P (MPa)Φ (°)C (MPa)Theoretical value (m)Measured value (m)Absolute error (%)Relative error (%)

Xinzhi [41]3002.632.30453.58.59.00.55.6
Yangcun [42]2731.203.47502.59.410.10.77.0
Liujiazhuang [43]3003.081.78424.515.816.91.16.5
Suntuan [44]4663.404.00365.315.617.01.48.2
Chenghe [45]3001.802.20453.89.510.00.55.0

Note. M represents the mining height.