Research Article

Comprehensive Structural Assessment of a Perforated Plate in the Edge and Central Crack

Table 4

Value of critical force obtained through analytical solution and solution by software.

Analytical solutionPcr-tahlili = 3616.223
Solution by software (the shell element)Pcr-shell = 3613.2
Solution by software (the solid element)Pcr-solid = 3596.7