Research Article

Tuning of Estimated Sound Absorption Coefficient of Materials of Reverberation Room Method

Table 6

Absolute error of the 64K25 estimation model.

FrequencyEstimated SAC of reverberation room methodSAC measured by reverberation room methodAbsolute error

1000.050.04−0.01
1250.080.08−0.01
1600.110.11−0.01
2000.160.170.00
2500.240.24−0.01
3150.330.31−0.03
4000.430.39−0.03
5000.640.54−0.10
6300.800.64−0.16
8000.810.73−0.08
10000.820.820.00
12500.830.890.05
16000.840.900.06
20000.860.910.06
25000.860.910.05
31500.850.84−0.01
40000.830.820.00
50000.780.820.04