Research Article
Static Characteristics of Finger Seal considering Contact between Fingers and Rotor
Table 1
Parameters of noncontacting finger seal.
| Parameters | Symbol | Value | Units |
| Finger base radius | Rb | 114.12 | mm | Stick arc radius | Rs | 110.00 | mm | Number of fingers | Nf | 80 | — | Rotor radius | Rr | 107.92 | mm | Foot upper radius | Rf | 109.22 | mm | Radius of circle of centers | Rcc | 25.20 | mm | Gap width | Gp | 0.38 | mm | Thickness of finger laminate | b | 1.00 | mm | Pad axial length | B | 0.64 | mm | Minimum height of the wedge | | 18 | μm | Maximum height of the wedge | | 36 | μm | Initial installation gap | hinit | 30 | μm |
|
|