Research Article
Effect of Ultrasonic Vibration on Forming Force in the Single-Point Incremental Forming Process
Table 5
Simulation setup and results with different step sizes.
| No. | Tool diameter (mm) | Number of step | Part depth (mm) | Step size (mm) | Amplitude (μm) | Forming force (N) |
| 1 | 10 | 24 | 6 | 0.5 | 15 | 916.0 | 2 | 10 | 24 | 6 | 0.5 | 0 | 929.5 | 3 | 10 | 12 | 6 | 1.0 | 15 | 1014.1 | 4 | 10 | 12 | 6 | 1.0 | 0 | 1021.6 | 5 | 10 | 8 | 6 | 1.5 | 15 | 1090.1 | 6 | 10 | 8 | 6 | 1.5 | 0 | 1096.1 |
|
|