Research Article

Study on Construction and Optimization of the Life-Saving Passage in Building Ruins Based on Numerical Simulation Method

Table 3

Timing test of shoring rescue technology.

NoEquipment typeShoring typeShoring height (mm)Number of testersProficiencyAverage time T

1Drama, claw hammer, handsaw, and consumablesDoor and window wood shoring18004Skilled28′32″
2Unskilled40′11″
32400Skilled31′16″
4Unskilled52′36″
53600Skilled44′48″
6Unskilled60′37″
7Double column wood shoring18004Skilled60′55″
8Unskilled81′23″
92400Skilled73′07″
10Unskilled94′03″
113600Skilled88′34″
12Unskilled102′16″
13L-type wood shoring18004Skilled66′30″
14Unskilled96′31″
152400Skilled67′22″
16Unskilled99′58″
173D wood shoring18004Skilled155′44″
18Unskilled189′02″
192400Skilled160′19″
20Unskilled199′32″
213600Skilled187′08″
22Unskilled220′51″