Research Article

The Influence of the Load Type on the Center Frequency Tuning of the Variable-Flux Biaxial Energy Harvester

Table 5

A center frequency comparison for the PSU up and down sweeps using 10, 100, and 1000 filter capacitors for 100 resistive load.

Filter capacitor value (up sweep) (down sweep) Max voltage in up sweep cycle (mv)Max voltage in down-sweep cycle (mv)

108.528.37907894
1008.728.17991969
10009.27.83661712