Research Article

Statistical Evaluation and Optimization of Factors Affecting the Leaching Performance of Copper Flotation Waste

Table 10

Analysis of variance for concentration of leached copper.

SourceDFSeq SSAdj SSAdj MS 𝐹 𝑃

Regression436208.1362089052.010.050.000
Linear324297.13617412057.913.39 0.000
pH1 6728.167286728.17.470.011
Stirring time116965.11696516965.1 18.84 0.000
Temperature1 603.91248112480.713.86 0.001
Square111911.01191111911.013.230.001
Temperature*temperature1 11911.011911 11911.013.23 0.001

Residual error2522512.522513900.5
Lack-of-fit 819249.3192492406.212.530.000
Pure error17 3263.33263192.0

Total2958720.6