Research Article

Development of Methane and Nitrous Oxide Emission Factors for the Biomass Fired Circulating Fluidized Bed Combustion Power Plant

Table 4

Test of reproducibility and method detection limit.
(a) Results of reproducibility

SubstanceResult of reproducibility test (area)Statistical data
123MeanSEaRSE (%)

CH49,7759,7679,7179,75318.150.186
N2O24,68924,93924,81124,813125.010.291

aStandard error (SE): standard deviation.
(b) MDL

Classification1234567MeanSDbMDL
ng

CH4Peak area724690764642655705679694410.013
N2OPeak area3,2322,6842,5743,6552,2211,6122,5742,6506610.074

bSD: standard deviation.