Research Article

Identification of Input Nonlinear Control Autoregressive Systems Using Fractional Signal Processing Approach

Table 8

Comparison of proposed results against true values of INCAR model for 3 dB SNR.

MethodDesign parametersMSE

(10−04, 10−08)VLMS1.350033 1.1514110.382217 1.2660461.237098
KLMS1.356493 0.7489640.105174 1.3620220.609956
FLMS11.352386 0.9929910.491026 1.6864560.849316
FLMS21.352534 0.9933160.490747 1.6864450.849539

(10−03, 10−05)VLMS1.349324 0.9834020.533690 1.4237011.105389
KLMS1.350614 1.1369700.030726 1.6128520.232501
FLMS11.351001 0.9931540.493843 1.6947380.819746
FLMS21.351107 0.9953500.492513 1.6939310.819381

True values1.350000 1.0000000.500000 1.6800000.840000