Research Article

Synthesis of Trigeneration Systems: Sensitivity Analyses and Resilience

Table 3

Sensitivity analysis for a variation in energy demands.

Variation−20%−10%0%+10%+20%

System composition
 Gas engines 22333
 Hot water boilers 33334
 Heat exchangers 33444
 Absorption chillers 11111
 Mechanical chillers 23334
 Cooling towers 33344

Natural gas (total) MWh/yr25,89626,34937,32438,30138,689
Purchased electricity MWh/yr092900
Sold electricity MWh/yr7340698111,38911,26910,905
Natural gas (cogeneration) MWh/yr24,89624,83136,63837,24637,189
Cogenerated electricity MWh/yr10,16210,13514,95415,20215,179
Cogenerated useful heat MWh/yr65986981860291619609

Primary energy savings %12.6513.9910.0111.0012.08
Equivalent electrical efficiency %57.8559.3655.2256.1757.25

Annual fixed cost €/yr369,035409,285510,830516,580563,730
Cost of natural gas €/yr647,391658,718933,092957,513967,215
Cost of electricity €/yr01076320700
Profit with the sale of electricity €/yr−565,160−537,535−876,960−867,692−839,669

Annual total cost €/yr451,266531,544570,169606,401691,275