Research Article
Mechanical Properties of Recycled Concrete in Marine Environment
Table 6
Comparison of test value and predicted values.
| No. | Corroding time (months) | Measured value (MPa) | Predicted value (MPa) | Relative error (%) |
| NC | 4 | 28.92 | 28.81 | 0.38 | 6 | 28.65 | 28.18 | 1.67 | 8 | 28.39 | 27.56 | 2.92 | 10 | 27.62 | 26.95 | 2.43 | 12 | 26.86 | 26.36 | 1.86 | 14 | 26.33 | 25.78 | 2.08 | 16 | 25.80 | 25.22 | 2.25 |
| RC-30 | 4 | 27.34 | 27.34 | 0 | 6 | 27.00 | 26.62 | 1.41 | 8 | 26.66 | 25.92 | 2.78 | 10 | 26.18 | 25.24 | 3.59 | 12 | 25.70 | 24.57 | 4.39 | 14 | 24.60 | 23.92 | 2.72 | 16 | 23.49 | 23.29 | 0.85 |
| RC-60 | 4 | 25.79 | 25.55 | 0.93 | 6 | 25.39 | 24.83 | 2.2 | 8 | 24.99 | 24.13 | 3.44 | 10 | 24.21 | 23.45 | 3.14 | 12 | 23.43 | 22.79 | 2.73 | 14 | 22.77 | 22.14 | 2.72 | 16 | 22.11 | 21.52 | 2.67 |
|
|