Research Article
Modeling and Simulation of Turbulent Flows through a Solar Air Heater Having Square-Sectioned Transverse Rib Roughness on the Absorber Plate
Table 2
Range of geometrical and operating parameters for CFD analysis.
| Geometrical and operating parameters | Range |
| Entrance length of duct, “” | 245 mm | Test length of duct, “” | 280 mm | Exit length of duct, “” | 115 mm | Width of duct, “” | 100 mm | Depth of duct, “” | 20 mm | Hydraulic diameter of duct, “” | 33.33 mm | Duct aspect ratio, “W/H” | 5 | Rib height, “” | 0.7, 1.0, 1.4 and 2.0 mm | Rib Pitch, “” | 10, 14.29, 20 and 28.58 mm | Reynolds number, “Re” | 3800–18,000 (6 values) | Prandtl number, “Pr” | 0.7441 | Relative roughness pitch, “” | 14.29 (fixed value) | Relative roughness height, “” | 0.021, 0.03, 0.042 and 0.06 |
|
|