Research Article
Water Plasma Functionalized CNTs/MnO2 Composites for Supercapacitors
Figure 5
(a) Cyclic voltammograms obtained at a scan rate of 10 mVs−1 for untreated MWCNTs/MnO2 and wpCNTs/MnO2 under different plasma conditions ((A): untreated, (B): 75 W, 135 Pa, (C): 140 W, 135 Pa, (D): 10 W, 135 Pa). (b) Cyclic voltammograms of nanocomposite wpCNTs/MnO2 (10 W, 135 Pa) at different scan rates, 10, 20, 30, 40, 50, 100, and 150 mVs−1.