Research Article

Numerical Simulation and Comparison of Conventional and Sloped Solar Chimney Power Plants: The Case for Lanzhou

Table 3

The comparison of the numerical result and the experimental data.

SourceTemperature increaseUpwind velocity

Experimental data20 K15 m/s
Fluent result21.5 K14.33 m/s