Research Article

Using Three-Dimensional Computational Modeling to Compare the Geometrical Fitness of Two Kinds of Proximal Femoral Intramedullary Nail for Chinese Femur

Table 2

The average fitness value on the middle and distal portion of the implant (mm).

InterTan ( )PFNA-II ( ) value

Impingement thickness on the middle shaft of the femur2.11 ± 0.361.62 ± 0.380.073
Impingement length on the middle shaft of the femur60.62 ± 8.3758.48 ± 7.380.361
Distance from the top of the great trochanter to the central of the impingement area154.43 ± 7.72148.74 ± 8.870.652
Distance between the nail and the inner cortex in the lateral view4.17 ± 0.35
( )
6.95 ± 0.68
( )
0.035