Research Article

Design and Experimental Validation for Direct-Drive Fault-Tolerant Permanent-Magnet Vernier Machines

Table 4

Comparison of inductances.

ItemsA-A A-BA-CA-DA-E

Inductance (mH)3.220.00330.01130.01130.0033
Ratio (%)1000.1020.350.350.102