Table 3
The summarized results of MRT and
.
| Experiments | Number of runs | MRT (s) | (%) |
| 1 | 1A | 154.25 | 1.58 | 2 | 3A | 136.40 | 12.97 | 3 | 5A | 151.54 | 3.31 | 4 | 7A | 156.17 | 0.35 | 5 | 8A | 141.31 | 9.83 | 6 | 2B | 128.78 | 18.60 | 7 | 4B | 129.85 | 18.14 | 8 | 6B | 131.38 | 17.0 | 9 | 9B | 134.57 | 14.30 |
|
|