Research Article

Optimization of Integrated Impeller Mixer via Radiotracer Experiments

Table 7

Comparisons of current technique using Taguchi method and other method.

Authors MethodParameters Results
(rpm) (mm) (mm) (mm) (lpm)MRT
(theo)
MRT
(exp)
(%)

Current studyIntegrated mixer
(dual impeller)
1005035021.85156.72156.050.39
[17]Single Rushton2881451140.532.642.4457.4
[12]Four stirrer paddles8003005253420
[18]Multibladed T-type blade502 m0.186 m30426.36
[19]Jet mixing1.92356363!

: speed, : clearance, : height, : diameter, : volumetric flow rates, MRT: mean residence time, theo: theoretical, and exp: experimental.