Research Article

Parameters Optimization for Magnetic Resonance Coupling Wireless Power Transmission

Table 2

Theoretical and experimental values of .

Experiment conditionsTheory Experiment
( mm) ( mm) ( mm)

0.101 (35)0.600 (0)0.4510.414 (3)
0.019 (100)0.414 (3)0.1790.176 (20)
0.050 (60)0.414 (3)0.3200.367 (5)
0.153 (25)0.353 (5)1.000*1.000*

The separation between coils is as close as possible, the same meaning as in Table 3.