Research Article
Management of Head and Neck Pseudoaneurysms: A Review of 33 Consecutive Cases
Table 1
Pseudoaneurysm intervention: breakdown of location and etiology.
| Management | Cases | Location | Etiology |
| Vessel deconstruction by coil and Onyx | 8 | ICA (4), VA (3), lingual | Iatrogenic (5), idiopathic (2), traumatic | Vessel deconstruction by coil | 7 | ICA (4), VA (3) | Idiopathic (4), traumatic (2), iatrogenic | Selective coiling | 6 | ICA (2), VA, Max, BA, STA | Idiopathic (3), iatrogenic (2), traumatic | Stent-assisted coiling | 6 | ICA (6) | Idiopathic (5), traumatic | Stent | 6 | ICA (4), VA (2) | Idiopathic (3), iatrogenic (2), traumatic |
|
|