Research Article

Unconventional Bearing Capacity Analysis and Optimization of Multicell Box Girders

Table 2

Comparative analysis of influential box girder parameters.

VariantThe geometrical parameters of the cross sectionAreaDeflection
Dimensions according to
ā€‰(mm)(mm) (mm) (mm) (mm) (mm) (mm) (mm) (cm2)(mm)

1Figure 11000600400101015883153.26
2Optimized110390036061514.5663052.00
3Adopted110090036061515663061.86