Research Article

Extension of Weighted Sum of Gray Gas Data to Mathematical Simulation of Radiative Heat Transfer in a Boiler with Gas-Soot Media

Table 2

Comparison of the calculated total emissivities using the coupled models, with the benchmarks °K and  Kg/m3.

Present model coupled by: Discrepancies (%) with “3-gas plus 2-soot”  
Truelove's model
Discrepancies (%) with “4-gas plus 2-soot”  
Truelove's model [12]
 m  m  m  m  m  m

Taylor's data−4.85−0.6795.25−6.71−10.88−2.46
3-term Truelove's data−0.768−1.832.49−2.70−11.92−5.02
4-term Truelove's data−5.14−3.61−3.98−6.99−13.51−3.64