Research Article
Extension of Weighted Sum of Gray Gas Data to Mathematical Simulation of Radiative Heat Transfer in a Boiler with Gas-Soot Media
Table 2
Comparison of the calculated total emissivities using the coupled models, with the benchmarks
°K and
Kg/m
3.
| Present model coupled by: |
Discrepancies (%) with “3-gas plus 2-soot” Truelove's model |
Discrepancies (%) with “4-gas plus 2-soot” Truelove's model [12] | m | m | m | m | m | m |
| Taylor's data | −4.85 | −0.679 | 5.25 | −6.71 | −10.88 | −2.46 | 3-term Truelove's data | −0.768 | −1.83 | 2.49 | −2.70 | −11.92 | −5.02 | 4-term Truelove's data | −5.14 | −3.61 | −3.98 | −6.99 | −13.51 | −3.64 |
|
|