Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response
Figure 7
Coefficients and , plotted as a function of , for both anemometers, Climatronics 100075 and Ornytion 107A. The linear fittings to the data have been included in the graphs for mm (in other words, they were calculated excluding the point mm).