Research Article

Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response

Table 3

Parameters and from the fittings of the proposed analytical model (with , see expression (24)), to the testing results (see Figure 6). The table also includes the slope, , the offset, , and determination coefficient of the linear fittings for each case.

[mm]   (= )   (= )

Climatronics 100075
400.6450−1.76184.4353−1.48740.9961
600.6505−1.69584.5983−1.52870.9747
800.6481−1.54944.5779−1.32970.9758
1000.6372−1.18014.4256−0.80350.6975
1200.6343−0.98894.3904−0.58100.6002

Ornytion 107A
400.6544−1.77314.5936−1.57840.9635
600.6570−1.73274.7082−1.64060.9972
800.6511−1.52384.6200−1.28950.9521
1000.6418−1.24094.4985−0.91160.8076
1200.6391−1.09474.4661−0.74070.9999