Research Article
Improved Power Control Using Optimal Adjustable Coefficients for Three-Phase Photovoltaic Inverter under Unbalanced Grid Voltage
Table 2
Comparison between calculation and simulation results for different power control coefficients.
| Coefficient group (, ) | Calculation value | /A | /V | /W | /Var | /VA |
| D (−0.8, −0.6) | 6.73 | 42.2 | 385.2 | 1329.3 | 574.0 | E (−1, −0.2) | 6.36 | 9.1 | 83.3 | 976.3 | 261.9 | F (−0.884, −0.290) | 6.30 | 4.1 | 37.4 | 1024.7 | 234.9 | G (0.2, −0.4) | 5.61 | 69.5 | 634.0 | 359.9 | 579.2 | H (−0.8, 0.6) | 6.99 | 132.4 | 1208.2 | 675.1 | 1101.6 | I (0.2, −0.2) | 5.49 | 63.9 | 582.6 | 409.6 | 548.0 | J (0.2, 0.6) | 5.72 | 45.2 | 412.5 | 633.7 | 456.7 | K (0.4, 0.8) | 6.30 | 46.9 | 427.8 | 915.0 | 525.2 |
| Coefficient group (, ) | Simulation value | /A | /V | /W | /Var | /VA |
| D (−0.8, −0.6) | 6.51 | 41.5 | 377.5 | 1321.5 | 566.3 | E (−1, −0.2) | 6.35 | 9.8 | 89.6 | 981.8 | 268.0 | F (−0.884, −0.290) | 6.34 | 3.8 | 34.4 | 1034.5 | 234.4 | G (0.2, −0.4) | 5.59 | 67.9 | 641.3 | 360.5 | 585.1 | H (−0.8, 0.6) | 6.83 | 132.2 | 1206.1 | 672.9 | 1099.5 | I (0.2, −0.2) | 5.56 | 61.4 | 577.6 | 413.7 | 544.8 | J (0.2, 0.6) | 5.75 | 43.6 | 407.2 | 638.4 | 453.4 | K (0.4, 0.8) | 6.31 | 45.4 | 423.2 | 909.6 | 520.5 |
|
|