Comparison of the maximum superimposed stress in the connectors at the maximum load level of 75 kN.
| Comparison of the maximum superimposed stress in the connectors | In - plane | In - plane | Superimposed stress | Axial direct stress | Bending stress | Superimposed stress | Axial direct stress | Bending stress |
| On-axis load | | | | | | | Value (MPa) | 114.15 | 59.50 | 54.65 | 82.35 | 82.35 | 0 | Ratio (%) | / | 52.12 | 47.88 | / | 100 | 0 | Off-axis load | | | | | | | Value (MPa) | 114.15 | 59.26 | 54.89 | 160.08 | 82.35 | 77.73 | Ratio (%) | / | 51.91 | 48.09 | / | 51.44 | 48.56 | Off-axis value to on-axis value ratio | 1.000 | 0.996 | / | 1.944 | 1.000 | / |
|
|