Research Article
Development of UHPC Mixtures Utilizing Natural and Industrial Waste Materials as Partial Replacements of Silica Fume and Sand
Table 9
Selected UPHC mixtures meeting the criteria for minimum required flow (180 mm) and 28-d compressive strength (150 MPa).
| Mix ID | Flow (mm) | 28-d compressive strength (MPa) | 28-d flexural tensile strength (MPa) |
| BMWR | 230 | 161 | 31 | NP60RMS | 195 | 154 | 29 | FA60RMS | 210 | 158 | 32 | LSP20RMS | 255 | 152 | 31 | CKD20RMS | 220 | 152 | 25 | PSS20RMS | 225 | 161 | 25 | LSP10RSAND | 215 | 163 | 29 | CKD05RSAND | 180 | 153 | 26 | PSS05RSAND | 210 | 161 | 24 | PSS10RSAND | 185 | 153 | 23 | PSS20RSAND | 180 | 160 | 24 |
|
|