Table of Contents Author Guidelines Submit a Manuscript
The Scientific World Journal
Volume 2014, Article ID 786185, 6 pages
http://dx.doi.org/10.1155/2014/786185
Research Article

Correlation between the Bone Mineral Density and Stress on Femur around a Duetto SI Stem

1Department of Medical Engineering and Technology, School of Allied Health Sciences, Kitasato University, 1-15-1 Kitasato, Minami Ku, Sagamihara, Kanagawa 252-0329, Japan
2Department of Orthopaedic Surgery, School of Medicine, Kitasato University, Sagamihara, Kanagawa, Japan
3Graduate School of Medical Sciences, Kitasato University, Sagamihara, Kanagawa, Japan

Received 19 April 2014; Revised 10 June 2014; Accepted 12 June 2014; Published 26 June 2014

Academic Editor: Ali Hosseini

Copyright © 2014 Rina Sakai et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. T. W. Phillips, L. T. Nguyen, and S. D. Munro, “Loosening of cementless femoral stems: a biomechanical analysis of immediate fixation with loading vertical, femur horizontal,” Journal of Biomechanics, vol. 24, no. 1, pp. 37–48, 1991. View at Publisher · View at Google Scholar · View at Scopus
  2. H. M. Frost, “Bone's mechanostat: a 2003,” The Anatomical Record A: Discoveries in Molecular, Cellular, and Evolutionary Biology, vol. 275, no. 2, pp. 1081–1101, 2003. View at Publisher · View at Google Scholar
  3. E. Garcia-Cimbrelo, E. Garcia-Rey, A. Cruz-Pardos, and R. Madero, “Stress-shielding of the proximal femur using an extensively porous-coated femoral component without allograft in revision surgery: a 5- to 17-year follow-up study,” Journal of Bone and Joint Surgery B, vol. 92, no. 10, pp. 1363–1369, 2010. View at Publisher · View at Google Scholar · View at Scopus
  4. M. G. Joshi, S. G. Advani, F. Miller, and M. H. Santare, “Analysis of a femoral hip prosthesis designed to reduce stress shielding,” Journal of Biomechanics, vol. 33, no. 12, pp. 1655–1662, 2000. View at Publisher · View at Google Scholar · View at Scopus
  5. E. Garcia-Cimbrelo, A. Cruz-Pardos, R. Madero, and M. Ortega-Andreu, “Total hip arthroplasty with use of the cementless Zweymüller Alloclassic system. A ten to thirteen-year follow-up study,” Journal of Bone and Joint Surgery A, vol. 85, no. 2, pp. 296–303, 2003. View at Google Scholar · View at Scopus
  6. K. Yamaguchi, K. Masuhara, S. Yamasaki, and T. Fuji, “Efficacy of different dosing schedules of etidronate for stress shielding after cementless total hip arthroplasty,” Journal of Orthopaedic Science, vol. 10, no. 1, pp. 32–36, 2005. View at Publisher · View at Google Scholar · View at Scopus
  7. B. Cohen and N. Rushton, “Accuracy of dexa measurement of bone mineral density after total hip arthroplasty,” Journal of Bone and Joint Surgery B, vol. 77, no. 3, pp. 479–483, 1995. View at Google Scholar · View at Scopus
  8. C. R. Wilson, I. Fogelman, G. M. Blake, and A. Rodin, “The effect of positioning on dual energy X-ray bone densitometry of the proximal femur,” Bone and Mineral, vol. 13, no. 1, pp. 69–75, 1991. View at Publisher · View at Google Scholar · View at Scopus
  9. T. A. Gruen, G. M. McNeice, and H. C. Amstutz, “'Modes of failure' of cemented stem-type femoral components. A radiographic analysis of loosening,” Clinical Orthopaedics and Related Research, vol. 141, pp. 17–27, 1979. View at Google Scholar · View at Scopus
  10. R. Sakai, Y. Sato, M. Itoman, and K. Mabuchi, “Initial fixation of a finite element model of an AI-Hip cementless stem evaluated by micromotion and stress,” Journal of Orthopaedic Science, vol. 15, no. 1, pp. 132–139, 2010. View at Publisher · View at Google Scholar · View at Scopus
  11. R. Sakai, A. Iwama, M. Itoman, and K. Mabuchi, “Rotational stability based on displacements obtained by simulation and measurement when torsion loading is applied to hip stems,” Journal of Orthopaedic Science, vol. 13, no. 3, pp. 248–254, 2008. View at Publisher · View at Google Scholar · View at Scopus
  12. J. H. Keyak, I. Y. Lee, and H. B. Skinner, “Correlations between orthogonal mechanical properties and density of trabecular bone: use of different densitometric measures,” Journal of Biomedical Materials Research, vol. 28, no. 11, pp. 1329–1336, 1994. View at Publisher · View at Google Scholar · View at Scopus
  13. P. M. Cattaneo, M. Dalstra, and L. H. Frich, “A three-dimensional finite element model from computed tomography data: a semi-automated method,” Proceedings of the Institution of Mechanical Engineers H, vol. 245, pp. 203–245, 2001. View at Google Scholar
  14. D. T. Davy, G. M. Kotzar, R. H. Brown et al., “Telemetric force measurements across the hip after total arthroplasty,” Journal of Bone and Joint Surgery A, vol. 70, no. 1, pp. 45–50, 1988. View at Google Scholar · View at Scopus
  15. P. B. Chang, B. J. Williams, K. S. B. Bhalla et al., “Design and analysis of robust total joint replacements: finite element model experiments with environmental variables,” Journal of Biomechanical Engineering, vol. 123, no. 3, pp. 239–246, 2001. View at Publisher · View at Google Scholar · View at Scopus
  16. W. R. Taylor, E. Roland, H. Ploeg et al., “Determination of orthotropic bone elastic constants using FEA and modal analysis,” Journal of Biomechanics, vol. 35, no. 6, pp. 767–773, 2002. View at Publisher · View at Google Scholar · View at Scopus
  17. N. Nuño and M. Amabili, “Modelling debonded stem-cement interface for hip implants: effect of residual stresses,” Clinical Biomechanics, vol. 17, no. 1, pp. 41–48, 2002. View at Publisher · View at Google Scholar · View at Scopus
  18. H. S. Bodén, O. G. Sköldenberg, M. O. Salemyr, H. Lundberg, and P. Y. Adolphson, “Continuous bone loss around a tapered uncemented femoral stem: a long-term evaluation with DEXA,” Acta Orthopaedica, vol. 77, no. 6, pp. 877–885, 2006. View at Publisher · View at Google Scholar · View at Scopus
  19. M. Galli, A. Leone, F. C. Tamburrelli, T. Pirronti, and A. G. Aulisa, “Periprosthetic mineralization changes around femoral stems: a prospective 12-month study with DEXA,” Skeletal Radiology, vol. 37, no. 8, pp. 723–729, 2008. View at Publisher · View at Google Scholar · View at Scopus
  20. E. Munting, P. Smitz, N. Van Sante, C. N. De Deuxchaisnes, A. Vincent, and J.-P. Devogelaer, “Effect of a stemless femoral implant for total hip arthroplasty on the bone mineral density of the proximal femur: a prospective longitudinal study,” The Journal of Arthroplasty, vol. 12, no. 4, pp. 373–379, 1997. View at Publisher · View at Google Scholar · View at Scopus
  21. H. Kröger, H. Miettinen, I. Arnala, E. Koski, N. Rushton, and O. Suomalainen, “Evaluation of periprosthetic bone using dual-energy x-ray absorptiometry: precision of the method and effect of operation on bone mineral density,” Journal of Bone and Mineral Research, vol. 11, no. 10, pp. 1526–1530, 1996. View at Google Scholar · View at Scopus
  22. C. A. Engh and P. Massin, “Cementless total hip arthroplaty using the anatomic medullary locking stem. Results using a survivorship analysis,” Clinical Orthopaedics and Related Research, no. 249, pp. 141–158, 1989. View at Google Scholar · View at Scopus
  23. R. Huiskes, H. Weinans, H. J. Grootenboer, M. Dalstra, B. Fudala, and T. J. Slooff, “Adaptive bone-remodeling theory applied to prosthetic-design analysis,” Journal of Biomechanics, vol. 20, no. 11-12, pp. 1135–1150, 1987. View at Publisher · View at Google Scholar · View at Scopus
  24. M. Paterson, P. Fulford, and R. Denham, “Loosening of the femoral component after total hip replacement. The thin black line and the sinking hip,” Journal of Bone and Joint Surgery B, vol. 68, no. 3, pp. 392–397, 1986. View at Google Scholar · View at Scopus
  25. P. Korovessis, P. Droutsas, G. Piperos, A. Michael, A. Baikousis, and M. Stamatakis, “Course of bone mineral content changes around cementless Zweymueller total hip arthroplasty: a 4-year follow-up study,” Archives of Orthopaedic and Trauma Surgery, vol. 116, no. 1-2, pp. 60–65, 1997. View at Publisher · View at Google Scholar · View at Scopus
  26. K. Nakamura, “Measurement of periprosthetic bone mineral density after cementless hip arthroplasty by dual energy X-ray absorptiomeiry: longitudinal and cross-sectional evaluation,” Journal of Orthopaedic Science, vol. 1, no. 2, pp. 113–122, 1996. View at Publisher · View at Google Scholar · View at Scopus