Clinical Study

Renal Function and Ultrasound Imaging in Elderly Subjects

Table 2

Overall performance of difference and accuracy between 24 h-CrCl and estimated GFR.

EquationsMean of difference ± SD  
(mL/min)
Accuracy within
15%30%50%

Cockcroft-Gault2.3 ± 20.20.49466988
MDRD−18.8 ± 26.90.28254472
CKD-EPI−9.1 ± 22.90.30335675