Research Article
The New Performance Calculation Method of Fouled Axial Flow Compressor
Table 2
Fouling severity assignment table [
4].
|
FS
| | | |
| 0 | 1.00 | 1.00 | 1.00 | 1 | 0.96 | 0.99 | 0.95 | 2 | 0.92 | 0.98 | 0.90 | 3 | 0.88 | 0.97 | 0.85 | 4 | 0.84 | 0.96 | 0.80 | 5 | 0.80 | 0.95 | 0.75 | 6 | 0.76 | 0.94 | 0.70 | 7 | 0.72 | 0.93 | 0.65 | 8 | 0.68 | 0.92 | 0.60 | 9 | 0.64 | 0.91 | 0.55 | 10 | 0.60 | 0.90 | 0.50 |
|
|