Research Article

Temperature Effects on the Magnetic Properties of Silicon-Steel Sheets Using Standardized Toroidal Frame

Table 3

Iron losses for a sinusoidal waveform and unipolar PWM (with = 50 Hz) obtained using the new toroidal frame.

Flux densityUnipolar PWM
= 0.3, = 20
Unipolar PWM
= 0.6, = 20
Unipolar PWM
= 0.9, = 20
Sinusoidal waveform
50 Hz

1.0 T2.66 W/kg2.21 W/kg1.94 W/kg1.71 W/kg
1.4 T5.46 W/kg4.31 W/kg3.80 W/kg3.25 W/kg