DCM computed average composition group volume fractions.

Area Imaging resolution
(μm)
Computed volume fractions (%) Computed time (s)
Group AGroup BGroup CGroup D

Area 03.74.4887.807.580.149.06 × 105
11.844.3788.007.510.126.55 × 104

Area 13.73.3086.909.400.402447
11.843.3986.909.310.4070

Area 23.75.2589.305.400.052428
11.844.9789.605.360.0779

Area 33.73.2785.4011.100.232274
11.843.3685.4011.000.2471

Area 43.74.8289.106.020.062366
11.844.6389.405.850.1272

Area 53.74.1488.507.220.142547
11.844.2588.207.370.1870

Area 63.74.3588.207.280.172415
11.844.2188.407.160.2373

Area 73.74.5289.206.170.112386
11.844.4189.406.070.1270