Annual and all-year simulations of electric-power output at various turbine hub heights in the study sites.

LocationPeriod = 10 m = 30 m = 50 m = 70 m = 90 mh = 110 m
(W) (W) (W) (W) (W) (W) (W) (W) (W) (W) (W) (W)

Katsina2006594.15595.16892.36668.211160.14671.111426.30651.171698.98622.031982.01589.36
2007770.20631.021132.89652.481450.87629.561761.74596.392075.95560.972398.30526.11
2008451.36542.15740.06687.381017.79722.661307.77713.841617.06684.671949.45646.34
2009434.31510.50662.90639.88872.75684.041084.56691.521304.28679.831534.82657.70
2010358.94429.31515.11555.42654.10619.67791.08652.84930.40666.701074.09667.82
All-year522.29559.58778.56654.691008.66675.011237.29667.531471.43647.051714.38620.28

Warri200672.8498.82118.44164.35164.63230.60214.57300.90269.40374.27329.85447.98
2007114.93151.77176.57238.51236.08319.68298.19398.27364.41472.06435.56538.36
2008119.20149.09169.11217.26215.11278.74261.43337.98309.34394.84359.47448.29
2009137.64171.08193.47246.69244.41313.05295.32374.93347.67432.23402.16484.14
2010127.99161.31183.15236.80234.12304.36285.56368.42338.86428.54394.73483.54
All-year107.96139.16159.66211.08208.60277.97258.89343.80311.81407.78368.02468.16

Calabar200665.5290.15110.08154.79156.27221.78207.09294.33263.69371.35326.89449.82
200781.59110.95133.15185.13185.31259.65241.66337.51303.50416.66371.65493.44
200866.6491.81112.24158.00159.57226.65211.66300.88269.73379.42334.60458.98
200964.2988.62108.47152.77154.41219.48205.06291.96261.59369.15324.80448.04
201054.8176.1994.61134.32136.78196.04183.92264.54237.15339.43297.27418.30
All-year61.7285.33104.94148.21150.15214.04200.22286.01256.30363.19319.22442.65