Research Article

A Double-Sided Linear Primary Permanent Magnet Vernier Machine

Table 2

Flux density harmonic phase at different positions (electrical degree).

1st6th12th18th

Position A−89.8179.6179.3−1.3
Position B−179.4−177.8−175.66.5
Position C90.4−179.4−179.11.6
Position D0.66−177.6−175.46.9