System configuration acts as a strong grid to test the performance of the SB 1700E inverter under varying the DC voltage.
| Number | Actual | Internal resistor of inverter | Reading Ω | Vdc (V) | I1 (A) | V1 (V) | P1 (W) | I2 (A) | V2 (V) | P2 (W) | S2 (VA) | Efficiency | P. F | DC side | AC side |
| 1 | 31.5 | 32.3 | 28 | 300 | 4.7 | 152 | 727 | 2.9 | 229 | 675 | 689 | 0.93 | 0.98 | 2 | 31.0 | 35.7 | 28 | 280 | 4.2 | 150 | 634 | 2.6 | 229 | 590 | 601 | 0.93 | 0.98 | 3 | 32.0 | 35.1 | 28 | 260 | 3.87 | 136 | 544 | 2.2 | 228 | 500 | 510 | 0.92 | 0.98 | 4 | 31.2 | 41.5 | 28 | 240 | 3.3 | 137 | 451 | 1.9 | 228 | 420 | 430 | 0.93 | 0.98 | 5 | 31.1 | 50.4 | 28 | 220 | 2.7 | 136 | 369 | 1.57 | 228 | 340 | 350 | 0.92 | 0.97 | 6 | 32.0 | 68.0 | 28 | 200 | 2 | 136 | 278 | 1.2 | 228 | 250 | 280 | 0.9 | 0.89 | 7 | 33.8 | 104.6 | 28 | 180 | 1.3 | 136 | 182 | 0.87 | 228 | 160 | 206 | 0.88 | 0.78 | 8 | 35.9 | 214.1 | 28 | 160 | 0.64 | 137 | 88 | 0.6 | 228 | 70 | 140 | 0.8 | 0.50 | 9 | 0 | 0 | 28 | 140 | The inverter switches off |
|
|