Experimental data relevant to the H2S loss over time in a Nalophan bag stored at temperature of 23°C and humidity of 20% and 60%. The bag tested was without any film inside (B-no film) and with the film inside. The surface of the internal film sheet was equal to 1900 cm2 (B-film 1900), 2580 cm2 (B-film 2580), and 3520 cm2 (B-film 3520), respectively. The data reported are the average of the results from three different tests performed at the same conditions.

Time [hr]23°C RH% 2023°C RH% 60
% H2S losses% H2S losses

B-no film30.92 ± 0.048%  ± 4%0.96 ± 0.024%  ± 2%
240.77 ± 0.0223%  ± 2%0.80 ± 0.00420%  ± 0.4%
300.67 ± 0.0333%  ± 3%0.78 ± 0.01122%  ± 1.1

B-film 190030.89 ± 0.0111%  ± 1%0.94 ± 0.026%  ± 2%
240.65 ± 0.0135%  ± 1%0.60 ± 0.04540%  ± 4.5%
300.53 ± 0.0347%  ± 3%0.54 ± 0.05146%  ± 5.1%

B-film 258030.89 ± 0.0211%  ± 2%0.87 ± 0.0213%  ± 2%
240.54 ± 0.0146%  ± 1%0.53 ± 0.01547%  ± 1.5%
300.39 ± 0.00261%  ± 0.2%0.47 ± 0.01653%  ± 1.6%

B-film 352030.84 ± 0.0416%  ± 4%0.86 ± 0.0214%  ± 2%
240.53 ± 0.0347%  ± 3%0.44 ± 0.01756%  ± 1.7%
300.28 ± 0.0171%  ± 1%0.37 ± 0.02063%  ± 2%