Research Article

Operational Characterization of Pressure Regulating Valves

Table 1

Results from the regulation uniformity test operated under the reference flow velocity of 1 m sāˆ’1.

Parameter PRV model
10 PSI15 PSI20 PSI

Declared preset pressure (kPa)68.65102.97138.27
Mean regulated pressure (kPa)60.80103.95134.35
Standard deviation of the regulated pressures (kPa)2.1282.0013.579
Coefficient of variation (%)3.51.92.7
Deviation between the mean regulated pressure and the declared preset pressure (%)11.50.72.3