Research Article

Evaluation of the Combined Effects of Heat and Lighting on the Level of Attention and Reaction Time: Climate Chamber Experiments in Iran

Table 1

Mean (SD) of parameters of continuous performance test in different experiment conditions.

Temperature Illuminance Parameter
Commission error
(number)
Omission
error
(number)
Response
time
(ms)
Correct response (number)

22°C200 lux0.51 ± 0.710.31 ± 0.61471.11 ± 43149 ± 0.93
500 lux0.35 ± 0.320.22 ± 0.31434.11 ± 22.41149.1 ± 8.71
1500 lux0.31 ± 0.510.12 ± 0.33426 ± 31149.3 ± 0.61

value0.0010.0010.0010.032

37°C200 lux0.81 ± 0.810.71 ± 0.83541.55 ± 52.11148.1 ± 1.11
500 lux0.91 ± 0.820.71 ± 0.83542.22 ± 55.41148.2 ± 1.22
1500 lux1 ± 0.911 ± 1543.51 ± 82 148 ± 51.51

value0.0020.0010.0090.002