Research Article
Evaluation of Occurrence, Concentration, and Removal of Pathogenic Parasites and Fecal Coliforms in Three Waste Stabilization Pond Systems in Tanzania
Table 5
FC concentration means of raw wastewater and effluents of anaerobic, facultative, and maturation ponds of the three WSP treatment systems.
| Type of wastewater | Morogoro WSP | Mwanza WSP | Iringa WSP | Cfu/100 ml | Log units/100 ml | Cfu/100 ml | Log units/100 ml | Cfu/100 ml | Log units/100 ml |
| Raw wastewater | 2.07 × 108 | 7.95 | 1.01 × 108 | 7.43 | 3.12 × 108 | 8.06 | Anaerobic pond(s) | 1.14 × 108 | 7.53 | 4.42 × 106 | 6.52 | 8.15 × 107 | 7.13 | Facultative pond(s) | 3.21 × 106 | 6.39 | 2.73 × 105 | 5.21 | 2.61 × 107 | 6.56 | Maturation pond(s) | 5.81 × 105 | 5.38 | 4.92 × 103 | 3.62 | 5.73 × 106 | 6.07 |
|
|
Note. WSP = waste stabilization pond; cfu = colony-forming unit.
|