Research Article

Boron Removal from Mining and Synthetic Effluents by Electrocoagulation Using Aluminum Electrodes

Table 2

EC data to estimate the operational cost of synthetic effluent for 30, 60, 90, and 120 minutes using a current (i) of 3.0 A and supporting electrolyte (ES) of 0.200 mol L−1, and for the mining effluent, for 90 minutes, using 3.0 A of current and 0.400 mol L−1 of supporting electrolyte.

EffluentTime (min)Potential (V)i (A)Vol. (L)ES (g)CE (Wh L−1)ME (g)

Synthetic3012.63.04.068.004.7250.503
Synthetic6012.53.04.068.009.3751.006
Synthetic9011.73.04.068.0013.1621.510
Synthetic12012.83.04.068.0019.2002.013
Mining903.53.04.029.803.9371.510