Research Article

Development and Validation of New Reverberation Chamber for Wireless Devices

Table 1

Requirements of reverberation chamber to develop.

ItemsRequirements

Start operating frequency650 MHz

Overall volume5.05 m3
(Internal dimensions)(1.4 m × 1.95 m × 1.85 m)

Working volume0.76 m3
(Rectangular dimensions) (0.835 m × 0.951 m ×0.954 m)

Standard deviationLess than 2.5 dB