Research Article

An Efficient ECG Denoising Method Based on Empirical Mode Decomposition, Sample Entropy, and Improved Threshold Function

Table 1

comparison of signal denoising results of the MIT-BIH database with WGN (20 dB) added.

ECG signalEMD soft thresholdWavelet soft thresholdEMD waveletProposed method

1001.85.75.66.0
1041.44.55.55.4
1050.84.34.46.7
1061.23.53.44.2
1150.14.44.75.2
2150.54.64.75.1
Average0.964.54.715.43