Research Article

[Retracted] Application of Optical Fiber Sensing Technology in Permeability Test of Three-Dimensional Physical Model of Medium and Long-Distance Diversion Tunnel

Table 5

Seepage pressure at each characteristic point under 15 m head (excavation 120 cm).

Osmometer noFeature point numberFeature point coordinates/mSeepage pressure at characteristic points/mEstimated seepage water pressure at corresponding points of prototype/m

110.72.0900.62.04 (2.02)204
220.72.0900.91.40 (1.33)140
330.72.0901.31.82 (1.78)182
440.72.0901.53.30 (3.20)330
550.72.0901.84.38 (4.13)438
660.72.0902.25.15 (5.12)515
770.72.7050.91.94 (1.87)194
880.73.3050.95.55 (5.41)555
990.73.3050.98.79 (8.67)879
10100.73.9200.911.94 (11.89)1 194

Note: the measured values are in brackets.