Research Article
Static and Dynamic Mechanical Properties of Long-Span Cable-Stayed Bridges Using CFRP Cables
Table 8
Dynamic characteristics of the two cable-stayed bridges with different types of cable plane.
| Frequency (Hz) | Modal characteristics | CFRP cable-stayed bridge | Steel cable-stayed bridge | Order | Inclined plane | Order | Parallel plane | Order | Inclined plane | Order | Parallel plane |
| 1 | 0.1067 | 1 | 0.1053 | 1 | 0.1045 | 1 | 0.1032 | Longitudinal floating + vertical bending of pylon | 2 | 0.1292 | 2 | 0.1292 | 2 | 0.1253 | 2 | 0.1254 | First lateral bending | 3 | 0.2046 | 3 | 0.2031 | 3 | 0.2095 | 3 | 0.2080 | First vertical bending | 13 | 0.5625 | | | 12 | 0.5529 | | | First torsion + lateral bending | 15 | 0.5949 | 11 | 0.4999 | 15 | 0.5849 | 11 | 0.4883 | First torsion |
|
|