Research Article

Parametric Study on the Seismic Response of Steel-Framed Buildings with Self-Centering Tension-Only Braces

Table 5

Geometric detail of braces of the 9-story frames.

StorySC-TOBBRB
PT tendonsHSS cableCore
Diameter (mm)Area (mm2)Diameter (mm)Area (mm2)Area (mm2)

7–933.99037034383510
4–638.811828050275130
1–343.614939063626120