Research Article

Preparation of Flame Retardant Modified with Titanate for Asphalt Binder

Table 6

Test results of asphalt with FRA-Ti.

  Softening point (°C)Penetration (0.1 mm)Ductility (5 cm/min, 10°C, cm)Elastic recovery (%)LOI (%)

Number 1468731.97626.9
Number 2458924.77529.2
Number 3489224.57829.8
Number 4518122.879.529.9
Number 54710022.87327.3
Number 6509022.37527.3
Number 74994297121.6
Number 8509430.27125.6
Number 9459920.37323.8