Research Article

Evaluation of Concrete Durability Performance with Sodium Silicate Impregnants

Table 7

Decrease ratio of electrical potential after 2 years.

Period (days)ConditionControlC typeI type

Decrease ratio of potential (21 MPa: %)
720Tidal100.093.688.6
Submerged100.091.882.4
Salt-sprayed100.078.569.2

Decrease ratio of potential (34 MPa: %)
720Tidal100.091.684.8