Research Article
Performance Analysis of CFRP Composite Strips Confined RC Columns under Axial Compression
Table 3
Test results of previous studies: strength enhancement ratio.
| Paper | Dimension or diameter of the column (mm) | Height of the column, (mm) | Confinement type | Type of fibre | Number of layers () | Strength value of unconfined column () kN | Strength value of FRP confined column () kN | Strength enhancement ratio / |
| Silva [32] | 150 | 750 | Full wrap | Normal modulus CFRP | 3 | 468.40 | 732.99 | 1.56 | Wang and Wu [40] | 150 | 300 | Full wrap | Normal modulus CFRP | 2 | 545.77 | 1317.79 | 2.41 | Wang and Hsu [47] | 300 | 900 | Full wrap | GFRP | 6 | 2127 | 4025 | 1.89 | Hadi [48] | 205 | 925 | Full wrap | Normal modulus CFRP | 3 | 552 | 871.3 | 1.58 | Punurai et al. [49] | 76 | 1200 | Full wrap | Normal modulus CFRP | 3 | 36.5 | 59.64 | 1.63 | Yaqub and Bailey [13] | 200 | 1000 | Full wrap | High modulus CFRP | 2 | 826 | 1356 | 1.64 | Quiertant and Clement [50] | 200 × 200 | 2500 | Full wrap | Normal modulus CFRP | 2 | 1211 | 1578 | 1.30 | Pham et al. [51] | 212 | 800 | Full wrap | High modulus CFRP | 3 | 942 | 2109 | 2.24 | Li et al. [52] | 152.4 | 609.6 | Full wrap | E Glass Fibre | 2 | 652.91 | 866.93 | 1.33 | Siddiqui et al. [53] | 150 | 1200 | Full wrap | Normal modulus CFRP | 3 | 258 | 647.12 | 2.51 | Sharma et al. [54] | 125 × 125 | 1200 | Full wrap | GFRP sheet | 2 | 303 | 596.11 | 1.97 | Present study | 125 | 800 |
Strip wrap (20 mm spacing) | Normal modulus CFRP | 2 | 252.13 | 401.23 | 1.58 | Present study | 125 | 800 | Normal modulus CFRP | 3 | 252.13 | 502.09 | 1.99 |
|
|
: strength value of unconfined column; : strength value of FRP confined column.
|