Research Article

Obtaining Martensitic Structures during Thixoforming of Hypoeutectic Gray Cast Iron

Table 3

Quantitative metallographic analysis of alloys (95% confidence interval).

ConditionPredominant type of graphiteGraphite (%)IAS (μm)Graphite flake length (μm)

As-castA7.5 ± 0.859.1 ± 43.857.5 ± 38.9
1145°CE8.6 ± 0.757.8 ± 19.733.1 ± 9.6
1135°CE8.8 ± 1.158.1 ± 22.532.5 ± 6.9
1300°C–0 sE9.5 ± 0.845.2 ± 15.425.2 ± 8.6
1300°C–30 sE10.1 ± 0.743.9 ± 16.122.9 ± 9.3
1300°C–60 sE9.8 ± 1.442.9 ± 16.625.3 ± 6.8
1300°C–90 sE10.3 ± 1.653.1 ± 24.131.3 ± 8.5